CONTACT RATING:Silver plated: 3A/120VAC or 28VDC; 1A/250VAC.
Gold plated: 0.4A/20VACor VDC
MECHANICAL LIFE:50,000 make-and-break cycles.
CONTACT RESISTANCE: 20 MΩ max. (initial value) @ 2-4VDC
100mA for both silver and gold plated contacts.
INSULATION RESISTANCE:1,000 MΩ min./1000VDC
DIELECTRIC STRENGTH: 1,000 Vrms min.@sea level. (initial value)
OPERATING TEMPERATURE: -40°C to 85°C